Air Core Inductor Calculator
The following is a design tool based on Weaver's formula which calculates the inductance of an air core inductor.
L = (d2 * n2) / (18d + 40l)
where:
L is inductance in micro Henrys,
d is coil diameter in inches,
l is coil length in inches, and
n is number of turns.